Replacement of Evapco Cooling Tower Drift Eliminators
HomeHome > Products > Cellular Type Eliminator > Replacement of Evapco Cooling Tower Drift Eliminators
Replacement of Evapco Cooling Tower Drift Eliminators

Replacement of Evapco Cooling Tower Drift Eliminators

Replacement of Evapco Cooling Tower Drift Eliminators NEWIN EVD eliminators Drift eliminators remove small droplets of w
Basic Info
Model NO. eliminator
Noise Level Low
Application Fields Industrial
Certification ISO, CTI
Condition New
Warranty One Year
Usage Cooling Tower
Application Replace for Cooling Tower
Height 145mm
Transport Package Wood Packing
Specification CTI
Trademark NEWIN
Origin China
HS Code 84195000
Production Capacity 15000 Sets /Year
Product Description

Replacement of Evapco Cooling Tower Drift Eliminators

NEWIN EVD eliminators

Drift eliminators remove small droplets of water that are entrained in the exhaust air to minimize the nuisance and health issues that they create if allowed to escape through the top of the tower along with the heated air. Drift eliminators are designed to create a tortuous path for the air stream. When the water droplets move through them, they are forced to change direction and impact the drift eliminator side walls, coalescing and draining back into the wet section of the cooling tower.
The drift eliminators are constructed of an inert polyvinyl chloride (PVC) plastic material which effectively eliminates corrosion of these vital components. They are assembled in sections to facilitate easy removal for inspection of the water distribution system.

EVD-145 Eliminator

Replacement of Evapco Cooling Tower Drift Eliminators

Feaures
- Anti-aging, high water absorption
-low airflow resistance, high strength
- easy installation and long service life
- can be the replacement of air inlet louver

Specification

Model--EVDPVC
Max.lengthdepend on customer demand
Widthdepend on customer demand
Height145mm
Continuous
operation tempperature
50ºC
Max.applicationtemp.
(short term)
60ºC
Color Black
ApplicationCounter flow cooling tower

Packing and Loading: LCL shipment: by plywood pallet/case/carton, FCL shipment: by container
Trade Terms: EXW, FOB, CFR,CIF, DDU.
Payment term: T/T, L/C, West UnionMinimum Order Quantity: 1000pcs

EVD drift eliminator Pictures --- cooling tower drift eliminator

Replacement of Evapco Cooling Tower Drift Eliminators

Packing & Shipment

Replacement of Evapco Cooling Tower Drift Eliminators


Physical and mechanical property
No.Itemsymbolunitindextest method
1densityρg/cm3≤1.55GB/T 1033 1-2008
2tensile strengthlengthwaysσtMPa≥42.0GB/T 13022-91
crosswise ≥38.0
3tear strengthlengthwaysσtrkN/m≥150GB/T 1130-91
crosswise ≥160
4Folded in half Coldness
Resistance Temperature
ordinary typetbºC≤-8DL/T 742-2001
Frigostabile type ≤-18
5oxygen indexOI--≥30GB/T 2406 1-2008

Replacement for other brand cooling towers:

Our drift eliminators are modular PVC drift eliminators that most of modern cooling towers which are easily re-fitted with our new PVC drift eliminators.They are perfect for older cooling towers as replacement.

Replacement of Evapco Cooling Tower Drift Eliminators

 

You may be also interested in below PVC Air Inlet Louver/Cooling Tower Air Intake Louver/Cooling Tower Louver/Cooling Tower Air Inlet Louver,
please visit to below website below for more details.
http://newinmachine.en.made-in-china.com
http://newinmachine.en.made-in-china.com
http://newinmachine.en.made-in-china.com

 

Contact person

 


Erin Lian
Cell: +86-18172211369
Tel : +86-755-23077266
*******************************************
Website : http://newinmachine.en.made-in-china.com
http://newinmachine.en.made-in-china.com